5 Operation Stages
When
lowering or raising an ITS device, there are 5 basic steps, or
stages that the Disconnect Unit goes through.
STAGE
2. The second stage is UNLOCKING.
Before lowering the camera, the Disconnect Unit must first be
raised approximately ¾ inch. During the slight raising
operation, the support arms will be pushed to one side by the
tracking guide to clear the support notches. Springs inside the
socket half of the connector compress as the Disconnect Unit is
raised. Electrical and signal contacts are still engaged during
this stage. Each Disconnect Unit has a built-in positive stop
that, when reached, will alert the operator to begin lowering
the camera. Every time the Disconnect Unit is raised from the
“locked” position, the support arms will move and unlock the
Disconnect Unit.


|